By National Council on Radiation Protection and Measurements

Show description

Read Online or Download Medical X-Ray, Electron Beam, and Gamma-Ray Protection for Energies Up to 50 Mev: Equipment, Design, Performance, and Use PDF

Similar nuclear books

Heat Transfer and Fluid Flow in Nuclear Systems

Warmth move and Fluid in stream Nuclear structures discusses issues that bridge the distance among the elemental ideas and the designed practices. The e-book is made out of six chapters that hide research of the predicting thermal-hydraulics functionality of huge nuclear reactors and linked heat-exchangers or steam turbines of varied nuclear platforms.

The Nuclear Receptor Facts: Book

The FactsBook sequence has demonstrated itself because the most sensible resource of simply available and actual evidence approximately protein teams. They use an easy-to-follow layout and are researched and compiled through specialists within the box. This Factsbook is dedicated to nuclear receptors. the 1st part offers an creation and describes the mode of motion of the receptors generally.

Fukushima: Impacts and Implications

The Fukushima nuclear catastrophe in March 2011 led Japan, and plenty of different international locations, to alter their strength guidelines. David Elliott reports the catastrophe and its international implications, asking even if, regardless of persevered backing by means of a few governments, the turning out to be competition to nuclear strength skill the top of the worldwide nuclear renaissance.

Extra info for Medical X-Ray, Electron Beam, and Gamma-Ray Protection for Energies Up to 50 Mev: Equipment, Design, Performance, and Use

Example text

The image resolution of any given screen is improved by direct magnification, as long as the tube focal spot is sufficiently small to avoid excessive geometric unsharpness. Long exposure times may also degrade image resolution significantly due to motion unsharpness. I t should be noted that the use of single emulsion film and a single screen, rather than double emulsion film and two screens, can increase resolution significantly while the system speed and noise are both simultaneously decreased.

The difference between the length of each x-ray beam edge and each light-field edge shall not be greater than two percent of the source to image receptor distance at the image receptor. (g)Means shaU be provided to align the center of the x-raybeam, the fulcrum and the center of the image receptor. (h)A device s M be provided that automatically terminates the body section radiographic'exposure at a preset time interval, angle or kerma at the mceptor. The operator shall be able to terminate the exposure at any time.

The effectiveness of this practice in reducing the more relevant average glandular dose is only moderate, and is achieved a t the cost of considerable loss of image contrast. (4) Non-dedicated units shall have a filter interlock system, unless the filter is not changed from its standard value during mammography. 2 can be verified by a qualified expert by visual examination of the equipment and by study of typical breast or breast phantom images. (b) Measurements of beam HVL and collimation as well as of the tube focal spot size shU be performed on initial machine installation and whenever major tube assembly service is needed; measurement of the cassette support x-ray transmission is ordinarily needed only at the time of initial installation.