Read or Download MIL-HDBK-1008C - Fire Protection for Facilities Engineering, Design, and Construction PDF

Best technique books

Nanoengineering of Structural, Functional and Smart Materials

During this number of 24 articles, participants describe their learn within the improvement of multifunctional fabrics which are powerful, light-weight and flexible. besides sensible details at the ways that they performed their paintings, individuals additionally 5 info on purposes in composite fabrics, electronics, biosensing and shrewdpermanent fabrics.

Machine Learning and Systems Engineering

A wide foreign convention on Advances in computer studying and platforms Engineering was once held in UC Berkeley, California, united states, October 20-22, 2009, below the auspices of the area Congress on Engineering and desktop technological know-how (WCECS 2009). desktop studying and structures Engineering comprises forty-six revised and prolonged study articles written by means of widespread researchers partaking within the convention.

Nanoreactor Engineering for Life Sciences and Medicine (Artech House Series Engineering in Medicine & Biology)

Nanoreactors are nanoscale autos for enzymes and sensors which are used to create actual and chemical reactions. Nanoreactor builders are at the cusp of amazing advances in scientific diagnostics and cures, tissue engineering, and mobile biology, and this authoritative source places bioengineers correct on the innovative.

Additional info for MIL-HDBK-1008C - Fire Protection for Facilities Engineering, Design, and Construction

Example text

9-STD. 9-STD. Automatic sprinklers and hydrant protection are not required for magazines, bunkers, and storage facilities similarly constructed and located. 10 Warehouses and Storage Facilities. These criteria apply to facilities (except ordnance) used for storage, shipping, receiving, packing, and processing of materials. 1 Sprinkler Protection. 68 m2) or greater. Sprinklers shall be provided for smaller facilities containing materials, equipment and supplies that are mission essential, pose a severe fire hazard, are of high monetary value, pose a safety or environmental health risk, or expose an important structure.

In hazardous material storage areas not containing flammable or combustible liquids, design ceiling sprinkler densities based on the storage of Class IV commodities in NFPA 231 or NFPA 231C. In water reactive areas, provide automatic sprinklers with an OS&Y valve to be locked in the closed position. Provide a metal sign indicating the OS&Y valve is to remain locked in the closed position unless a fire is detected in the storage area. The sign can be attached to a chain and connected to the OS&Y valve or fastened permanently to the wall provided it does not interfere with the operation of the valve.

Horizontal flame spread can be rapid. The narrower the aisles and the higher the storage, the less ceiling sprinkler water penetration is delivered to control the fire. 1 Requirements. Protection of bin storage stacked in rack configuration shall be in accordance with NFPA 231C. Combustible bins in racks present a greater fire hazard and require a 10 percent increase in ceiling density or one additional level of in-rack sprinklers. Bin storage not stacked in a rack configuration shall be protected in accordance with NFPA 231.